Detection Method |
Dual Element PIR & Microwave Pulse Doppler |
|
PIR Sensitivity |
1.6°C at .6 m/sec (3°F at 2ft/sec) |
|
PIR Detection Speed |
1 to 5 ft/sec (0.3 to 1.5 m/sec) |
|
Maximum Ripple |
2.4 VDC Peak to Peak at 12 VDC |
|
Power Input |
7.8 to 16 VDC |
|
Current Draw |
Active: 28 mA Standby: 22mA |
|
Bi-Directional Temperature Compensation |
Yes |
|
Pulse Count |
1,2, - 2 to 3 Automatic depending on speed spectrum analysis |
|
Alarm Period |
2+/-1 sec |
|
Alarm Output |
N.C 28 VDC 0.1A with 10 Ohm series protection resistor |
|
Tamper Switch |
N.C 28 VDC 0.1A open when cover is removed |
|
Warm Up Period |
20 sec |
|
LED Indicator |
LED is blinking during warm up period and self testing
LED ON during alarm:
RED LED: Unit Alarm,
GREEN LED: PIR Channel,
YELLOW LED: MW Channel |
|
Operating Temperature |
-4°F to +140°F (-20°C to +60°C) |
|
RFI Protection |
30V/m 10-1000 MHz |
|
EMI Protection |
50,000 V of electrical interference from lightning or power through |
|
Visible Light Protection |
Immune against halogen light at 8 ft (2.4m) or 50,000 lux or reflected light |
|
Range on Center Axis |
60ft (18m) |
|
Angle Of Horizontal Coverage |
105° |
|
Number of PIR Zones |
52 |
|
MW Output Power |
MIN + 13 dBm IERP |
|
MW Frequency Setting Accuracy |
+/-3 MHz |
|
MW Center Frequency |
10.525 GHz |
10.687 GHz |
9.9 GHz |
|
MW Harmonic Emission |
-7.3 dBm |
-30 dBm |
-20 dBm |
|
Application |
USA FCC PART 15 |
MPT 1349 |
FRENCH PTT |
|
Weight |
5oz (140gr) |
6.7oz (190gr) |
6.7oz (90gr) |
|
Dimensions |
5.3" (137 mm) x 2.8" (70 mm) x 2.1" (53 mm) |